home *** CD-ROM | disk | FTP | other *** search
/ The CICA Windows Explosion! / The CICA Windows Explosion! - Disc 2.iso / nt / ntkb.zip / NTKB.EXE / Q108 / 4 / 11.TXT next >
Text File  |  1993-12-16  |  3KB  |  72 lines

  1. DOCUMENT:Q108411  15-DEC-1993  [W_NT]
  2. TITLE   :Configuring IRQ of Future Domain 8xx SCSI Controller
  3. PRODUCT :Windows NT
  4. PROD/VER:3.10
  5. OPER/SYS:WINDOWS
  6. KEYWORDS:
  7.  
  8. --------------------------------------------------------------------------
  9. The information in this article applies to:
  10.  
  11.  - Microsoft Windows NT operating system version 3.1
  12.  - Microsoft Windows NT Advanced Server 3.1
  13. --------------------------------------------------------------------------
  14.  
  15. SUMMARY
  16. =======
  17.  
  18. By default, the Future Domain 8xx SCSI controller operates with IRQ set to
  19. 5. If the adapter is configured to use a different interrupt, the
  20. corresponding registry entry needs to be changed manually.
  21.  
  22. MORE INFORMATION
  23. ================
  24.  
  25. The Setup applet of the Future Domain SCSI adapter does not have a dialog
  26. box that you can use to change any settings for the adapter. All settings
  27. in the registry are automatically set to their default values. As a result
  28. of this, if the IRQ level of the adapter is set to a non-default value
  29. (such as any number other than five), the system will not start properly.
  30.  
  31. WARNING: Using the Registry Editor incorrectly can cause serious, system-
  32.    wide problems that may require you to reinstall Windows NT to correct
  33.    them. Microsoft cannot guarantee that any problems resulting from the
  34.    use of Registry Editor can be solved. Use this tool at your own risk.
  35.  
  36. Modify the value "DriverParameter:REG_SZ:IRQ=5" in the following way:
  37.  
  38. 1. Start Registry Editor (REGEDT32.EXE) and select the following subkey:
  39.  
  40.       HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Services\Fd8xx
  41.       \Parameters\Device0
  42.  
  43. 2. Double-click the value DriverParameter:REG_SZ:IRQ=5.
  44.  
  45. 3. Enter the following string
  46.  
  47.       IRQ=<value_nr>
  48.  
  49.    where "<value_nr>" is the new value on which the controller operates
  50.  
  51. 4. Quit Registry Editor and restart Windows NT (or Windows NT Advanced
  52.    Server).
  53.  
  54. Additional reference words: 3.10
  55. KBCategory:
  56. KBSubCategory: HRDWR KEYREG
  57.  
  58. =============================================================================
  59.  
  60. THE INFORMATION PROVIDED IN THE MICROSOFT KNOWLEDGE BASE IS
  61. PROVIDED "AS IS" WITHOUT WARRANTY OF ANY KIND.  MICROSOFT DISCLAIMS
  62. ALL WARRANTIES, EITHER EXPRESS OR IMPLIED, INCLUDING THE WARRANTIES
  63. OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE.  IN NO
  64. EVENT SHALL MICROSOFT CORPORATION OR ITS SUPPLIERS BE LIABLE FOR
  65. ANY DAMAGES WHATSOEVER INCLUDING DIRECT, INDIRECT, INCIDENTAL,
  66. CONSEQUENTIAL, LOSS OF BUSINESS PROFITS OR SPECIAL DAMAGES, EVEN IF
  67. MICROSOFT CORPORATION OR ITS SUPPLIERS HAVE BEEN ADVISED OF THE
  68. POSSIBILITY OF SUCH DAMAGES.  SOME STATES DO NOT ALLOW THE EXCLUSION
  69. OR LIMITATION OF LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES
  70. SO THE FOREGOING LIMITATION MAY NOT APPLY.
  71.  
  72. Copyright Microsoft Corporation 1993.